Common make net recovery warnings

From Wiki-UX.info
Jump to: navigation, search

Incorrect tools version

WARNING: The version of the tools used for system recovery on "<server_hostname>" is 
         older than the version found on the server system "client_hostname". It is 
         recommended that you update Ignite-UX to the same version. You can do 
         this by using the command: /usr/sbin/swinstall -x 
         mount_all_filesystems=false -s 
         <server_hostname>:/var/opt/ignite/depots/recovery_cmds "*" 

This warning is issue because the client Ignite-UX recovery software version in the client is older that the version currently installed in the Ignite-UX server. Update the version of the IUX-Recovery bundled published on the Ignite-UX server on /var/opt/ignite/depots/recovery_cmds depot.

1. Remove the IUX-Recovery or any older Ignite-UX software from the client.
2. Check that /var/opt/ignite/depots/recovery_cmds depot exists on the Ignite-UX server


Example:

# swlist -l depot -s <server_hostname> | grep recovery_cmds
  /var/opt/ignite/depots/recovery_cmds

# swlist -l bundle -s <server_hostname>:/var/opt/ignite/depots/recovery_cmds
# Initializing...
# Contacting target "<server_hostname>"...
#
# Target:  <server_hostname>:/var/opt/ignite/depots/recovery_cmds
#

  IUX-Recovery          C.7.6.100      Ignite-UX network recovery tool subset
  Ignite-UX-11-11       C.7.6.100      HP-UX Installation Utilities for Installing 11.11 Systems
  Ignite-UX-11-23       C.7.6.100      HP-UX Installation Utilities for Installing 11.23 Systems
  Ignite-UX-11-31       C.7.6.100      HP-UX Installation Utilities for Installing 11.31 Systems
  • Note: If this is the first Ignite-UX client added to the Ignite-UX server, the the recovery_cmds depot will not available. The depot is created automatically by the /opt/ignite/bin/ignite interface the first time that a client is added. Alternative, the depot can be created using the "pkg_rec_depot" command.


Example:

# /opt/ignite/lbin/pkg_rec_depot
3. Install the latest "IUX-Recovery" bundle from the Ignite-UX server or add the client to the server using the Ignite-UX [ TUI | GUI ].


Example:

# swinstall -s <server_hostname>:/var/opt/ignite/depots/recovery_cmds IUX-Recovery @

=======  06/30/08 17:58:39 MDT  BEGIN swinstall SESSION
         (non-interactive) (jobid=<client_hostname>-0094)

       * Session started for user "root@<client_hostname>".

       * Beginning Selection
       * Target connection succeeded for "<client_hostname>:/".
       * Source connection succeeded for
         "<server_hostname>:/var/opt/ignite/depots/recovery_cmds".
       * Source:
         <server_hostname>:/var/opt/ignite/depots/recovery_cmds
       * Targets:                <client_hostname>:/
       * Software selections:
             IUX-Recovery,r=C.7.6.100,a=HP-UX_B.11.11_32/64,v=HP
             Ignite-UX.CD-TOOLS,r=C.7.6.100,a=HP-UX_B.11.11_32/64,v=HP,fr=C.7.6.100,fa=HP-UX_B.11.11_32/64
             Ignite-UX.CD-TOOLS-DOC,r=C.7.6.100,a=HP-UX_B.11.11_32/64,v=HP,fr=C.7.6.100,fa=HP-UX_B.11.11_32/64
             Ignite-UX.CD-TOOLS-SRC,r=C.7.6.100,a=HP-UX_B.11.11_32/64,v=HP,fr=C.7.6.100,fa=HP-UX_B.11.11_32/64
             Ignite-UX.DVD-TOOLS,r=C.7.6.100,a=HP-UX_B.11.11_32/64,v=HP,fr=C.7.6.100,fa=HP-UX_B.11.11_32/64
             Ignite-UX.DVD-TOOLS-DOC,r=C.7.6.100,a=HP-UX_B.11.11_32/64,v=HP,fr=C.7.6.100,fa=HP-UX_B.11.11_32/64
             Ignite-UX.DVD-TOOLS-SRC,r=C.7.6.100,a=HP-UX_B.11.11_32/64,v=HP,fr=C.7.6.100,fa=HP-UX_B.11.11_32/64
             Ignite-UX.IGNT-OBAM-RUN,r=C.7.6.100,a=HP-UX_B.11.11_32/64,v=HP,fr=C.7.6.100,fa=HP-UX_B.11.11_32/64
             Ignite-UX.MGMT-TOOLS,r=C.7.6.100,a=HP-UX_B.11.11_32/64,v=HP,fr=C.7.6.100,fa=HP-UX_B.11.11_32/64
             Ignite-UX.RECOVERY,r=C.7.6.100,a=HP-UX_B.11.11_32/64,v=HP,fr=C.7.6.100,fa=HP-UX_B.11.11_32/64
       * Selection succeeded.


       * Beginning Analysis and Execution
       * Session selections have been saved in the file
         "/.sw/sessions/swinstall.last".
       * "<client_hostname>:/":  1 software objects had their check script return
         the code indicating that the software will be excluded from
         further processing.
       * "<client_hostname>:/":  1 filesets were determined to be skipped in the
         analysis phase.
       * Analysis and Execution succeeded.


NOTE:    More information may be found in the agent logfile using the
         command "swjob -a log <client_hostname>-0094 @ <client_hostname>:/".

=======  06/30/08 17:59:01 MDT  END swinstall SESSION (non-interactive)
         (jobid=<client_hostname>-0094)
4. Verify the IUX-Recovery installation.


Example:

# swlist -l fileset -a state IUX-Recovery
# Initializing...
# Contacting target "<client_hostname>"...
#
# Target:  <client_hostname>:/
#

# IUX-Recovery
# IUX-Recovery.Ignite-UX
  IUX-Recovery.Ignite-UX.CD-TOOLS       configured
  IUX-Recovery.Ignite-UX.CD-TOOLS-DOC   configured
  IUX-Recovery.Ignite-UX.CD-TOOLS-SRC   configured
  IUX-Recovery.Ignite-UX.DVD-TOOLS      configured
  IUX-Recovery.Ignite-UX.DVD-TOOLS-DOC  configured
  IUX-Recovery.Ignite-UX.DVD-TOOLS-SRC  configured
  IUX-Recovery.Ignite-UX.MGMT-TOOLS     configured
  IUX-Recovery.Ignite-UX.RECOVERY       configured

Volume group /dev/vg00 partially included

WARNING: The volume group /dev/vg00 will be only partially included in the 
         System Recovery Archive.  This means that not all files and 
         directories on this volume group will be restored when the archive is 
         installed.  This message can be suppressed using the "-P s" option for 
         make_net_recovery. See make_net_recovery(1M) for more
         details.

This warning is issue when no all mount points or file systems on bootable volume group /dev/vg00 are included in the make_net_recovery procedure. This is the default behavoir of [ make_net_recovery | make_tape_recovery ] commands, but normally will not provided comprensive enough backup of the bootable volume group. Instead of disable the warning using the "-P s" flag, include all /dev/vg00 using the "-x inc_entire=vg00" flag.


Example:

# make_net_recovery -s <server_hostname>
-x inc_entire=vg00

Warning list_expander

WARNING: list_expander returned a warning; please check the recovery.log file 
         for details.
return code 2

This warning is issue due to issues encounter by list_expander command to stat the files to be included in the pax (tar format) recovery archive. If encounter, review the "recovery.log" file to check the specific causes and proceed as required.

Authors